Specifications
      Show Part Numbers

Following are the specifications for the Quantum DLT-V4 Internal tape drive with SATA interface.

Feature Specification
Performance
Formatted Capacity, Native Mode 160 gigabytes (GB)
Formatted Capacity, Compressed Mode1 320 GB
Interface SATA
Tape Drive Type DLT Derivative, streaming, 160 GB; 16-bit LVD
Recording Type Partial Response Maximum Likelihood (PRML)
Read Compatibility2 DLT-V4, DLT VS160, DLT VS80 / DLT1
Write Compatibility DLT-V4
Form Factor 5.25-inch, half-height
Sustained Transfer Rate, Native Mode Up to 10 megabyte (MB) per second
Sustained Transfer Rate, Compressed Mode1 Up to 20 MB/sec
Burst Transfer Rate 160 MB/sec
Error Rate (Unrecoverable) 1 in 1017 bits (non-media error)
Timing Characteristics
Read/Write Tape Speed 118 inches per second
Rewind Tape Speed 160 inches per second
Linear Search Tape Speed 118 inches per second
Average Rewind Time 68 seconds
Maximum Rewind Time 135 sec
Average Access Time (BOT) 84 sec
Maximum Access Time (from BOT) 168 sec
Load to BOT - Previously Recorded Tape 90 sec
Unload from BOT 22 sec (no brush), 61 sec (brush)
Data Cartridge and Media Characteristics
Media Width 0.5 inch
Media Length 1,847 ft
Media Type Metal Particle
Data Cartridge Dimensions 4.1 × 4.1 × 1.0 inches
Shelf Life 30 years minimum at 20° C and 40% relative humidity (non-condensing)
Usage 600 hrs (150 full read/write uses)
Physical
Dimensions (H × W × L) 1.656 × 5.807 × 8.874 inches (42.05 × 147.50 × 225.40 mm)
Weight 3.00 lb. (1.36 kg)
Reliability
Head Life 30,000 tape motion hours
MTBF 250,000 hours
Load/Unload 50,000 cycles
Environmental
Temperature Range
  • Operating: 10° C to 40° C (50° F to 104° F)
  • Storage: -40° C to 66° C (-40° F to 150.8° F)
  • Airflow 3.0 CFM, minimum
    Wet Bulb Temperature
  • Operating: 25° C (77° F)
  • Storage: 46° C (114.8° F)
  • Temperature Gradient
  • Operating: 11° C (19.8° F) per hour (across range)
  • Storage: 20° C (36° F) per hour with 5° margin (across the range)
  • Temperature Shock
  • Operating: 10° C (18° F) over two minutes
  • Storage: 15° C (27° F) with 5° margin (over two minutes)
  • Relative Humidity
  • Operating: 20% to 80% non-condensing
  • Storage: 10% to 95% non-condensing
  • Humidity Gradient
  • Operating: 10% per hour
  • Storage: 10% per hour
  • Operating Altitude -500 feet to 30,000 feet
    Certifications
    Emissions
  • FCC CFR Part 15 Class B (ANSI C63.4: 1992, CISPR22: 1997)
  • EMC Directive (89/336/EEC)
  • EN 55022: 1998, +A1:2000, +A2:2003 Class B
  • IEC/CISPR 22: 1997, +A1:2000, +A2: 2003 Class B
  • VCCI-03:2004 Class B
  • CNS 13438
  • AS/NZS 3548
  • ICES - 0003
  • Safety Requirement
  • Low Voltage Directive (73/23/EEC)
  • UL 60950 - US Standard: Safety of Information Technology Equipment including Electrical Business Equipment
  • CSA C22.2 #950 - Canadian Standard: Safety of Information Technology Equipment including Electrical Business Equipment
  • EN 60950-1:2001, 1st Edition - European Standard: Safety of Information Technology Equipment including Electrical Business Equipment
  • 1 Compressed values use a nominal 2:1 compression ratio. Actual compression ratios achieved depend on the redundancy of data files being recorded.
    2 Performance may vary when the tape drive reads data previously written to the DLT VS80 and DLT1 formatted data cartridges. Performance depends on the quality of the data cartridge you are reading, not the DLT-V4 tape drive.