SCSI Bus Cable
Part number 5502640,5502642,5502643,5502645,5502671

SE mode:
The maximum cumulative cable length when using a single-ended transceiver should be 3 meters. Implementations that limit the transfer rate to a maximum of 5 megabyte transfers per second may extend the cumulative cable length to 6 meters. (ANSI SCSI-3 X3T10/855D). The maximum cumulative signal path between terminators shall be 3.0 meters when using up to 4 maximum capacitance (25pF) devices. The maximum cumulative signal path length between terminators shall be 1.5 meters when using from five to eight maximum capacitance devices. (ANSI SCSI-3 FAST-20 X3T10/1071D).

LVD mode:
The maximum cumulative cable length when using an LVD transceiver must comply to the limit, which is defined by ANSI SCSI-3 X3T10/855D. The maximum cumulative signal path between terminators shall be 12 meters when using up to 4 maximum capacitance (25pF) devices. The maximum cumulative signal path length between terminators shall be 12 meters when using from five to eight maximum capacitance devices. (ANSI SCSI-3 FAST-20 X3T10/1071D).