Specifications
      Show Part Numbers

975 2U Rack Mount Server Specifications
Case Dimensions (H × W × D) 3.504 × 16.93 × 25.51 inches (89 × 430 × 648 mm)
Color Black trim with black bezel
Form Factor 2U rack-mount server chassis for EIA Standard 310-D racks
Drives/Bays
  • LVD SCSI Backplane with Fast, Ultra, Ultra-80, Ultra-160, and Ultra-320 support for up to six 1-inch hot-swap drives
  • One slim-line CD-ROM/Floppy disk drive module
  • One 3.5-inch full-height bay
  • System Cooling
  • Four 60-mm fans mounted in the middle of the chassis and instrumented to provide RPM data for fan-failure prediction and detection
  • One 60-mm × 38-mm power supply module fan
  • Front Panel Buttons and Switches
  • Power on/off (momentary) button
  • System-reset button
  • ACPI sleep switch
  • Tool-activated NMI switch
  • Front Panel LEDs
  • Power
  • Hard drive status
  • Network activity
  • System ID
  • System status
  • Front Panel Connectors
  • Video (switched video with rear video connector)
  • USB port
  • Security A mechanical lock on the optional front bezel and an intrusion switch that can be monitored by Intel® Server Management software
    Power Supply Refer to the Specifications page for the power supply
    Environmental
    Temperature
  • Maximum rate of change: 18°F (10°C) per hour
  • Non-operating: -55° to 150°F (-48.3° to 65.5°C)
  • Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every 1,000 feet (305 meters).
    Note:Use of 2 GB DIMMs derates the server to 86°F (30°C)
  • Altitude 10,000 feet (3,048 meters) maximum
    Humidity
  • Nonoperating: 95% relative (non-condensing) at 86°F (30°C)
  • Operating wet bulb: Not to exceed 91.4°F (33°C) (with floppy disk drive or hard drive)