| Height | 1.693 inches (43 mm) |
| Width | 16.93 inches (430 mm) |
| Depth | 23.89 inches (609.2 mm) |
| Color | Black trim with black bezel |
| Form factor | 1U rack-mount server chassis for EIA Standard 310-D racks |
| Drive bays | LVD SCSI Backplane with Fast, Ultra, Ultra-80, Ultra-160, and Ultra-320 support for up to three 1-inch hot-swap drives and one slim-line CD-ROM/Floppy module |
| System cooling | Five 40-mm fans mounted in the middle of the chassis and instrumented to provide RPM data for fan-failure prediction and detection
Two 40-mm power-supply fans |
| Front panel buttons and switches | Power on/off (momentary) button System-reset button ACPI sleep switch Tool-activated NMI switch |
| Front panel LEDs | Power Hard drive status Network activity System ID System status |
| Front panel connectors | Video (switched video with rear video connector) USB port |
| Security | A mechanical lock on the optional front bezel and an intrusion switch that can be monitored by Intel® Server Management software |
| Power supply | Refer to the Specifications page for the power supply |
| Environmental |
| Temperature | Maximum rate of change: 18°F (10°C) per hour Nonoperating: -55° to 150°F (-48.3° to 65.5°C) Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every 1,000 feet (305 meters). Use of 2 GB DIMMs derates the server to 86°F (30°C) |
| Altitude | 10,000 feet (3,048 meters) maximum |
| Humidity | Operating wet bulb: Not to exceed 91.4°F (33°C) (with floppy disk drive or hard drive) Nonoperating: 95% relative (noncendensing) at 86°F (30°C) |