Specifications
Part number 3501129,3501224

System Specifications

    The following specifications are for the standard configuration. The server may contain optional equipment. All specifications are subject to change.

    Case size

    8.6-in. (21.84 cm) x 28.8-in. (73.15 cm) x 17.4-in. (44.2 cm) (W x D x H)

    Note: with outriggers and castors, system is 20-in. (50.8 cm) high

    Processors

    As many as two Pentium IIITM (FC-PGA Socket 370) processors operating at 667 MHz and faster with 133 MHz front-side bus

    RAM

    Four DIMM sockets support up to 4.0 GB of PC/133 Interleaved SDRAM

    BIOS

    Flash BIOS for easy updates from diskette

    IDE interfaces

    Supports as many as four ATAPI/IDE devices (hard drives, CD drives) using two onboard PCI IDE adapters

    Diskette drive interface

    Diskette controller is integrated on the system board

    I/O ports

    One parallel port, one serial port, two USB ports, one PS/2 keyboard port, one PS/2 mouse port, video port, and RJ-45 LAN port. LPT and COM ports configurable from system setup program. No jumper settings required.

    SCSI interfaces

    AIC 7899W U160

    Network interface

    Intel 82544 10/100/1000 NIC

    Video

    Integrated ATI Rage-XL PCI-based VGA controller with 4 MB of PC100 SDRAM.

    Expansion slots

    Six PCI slots:
    four 64-bit, 66 MHz (3.3v)
    and two 32-bit, 33 MHz (5v))

    Power supply

    350 W redundant power supply

    Certification

    FCC Class A, UL, CUL, CD Mark, VCCI, CB Scheme

Environmental specifications

    The following specifications identify maximum environmental conditions. At no time should the server run under conditions which violate these specifications.

Variable Requirements

Temperature

Maximum rate of change = 10° C per hour


Nonoperating

-48.3° to 65.5° C (-55° to 150° F)


Operating

5° to 35° C (41° to 95° F); derated 0.5° C for every 1000 ft. (305 m)

Altitude

10,000 ft. max

Humidity



Nonoperating

95% relative (noncondensing) at 30° C (86° F)


Operating wet bulb

Not to exceed 33 °C (91.4° F) (with diskette drive or hard drive)

Shock



Operating

2.0 g, 11 msec, 1/2 sine


Packaged

Operational after 30-inch free fall (cosmetic damage might occur)

AC Input Power



100-120 V~

100-120 V~, 6 A, 50/60 Hz


200-240 V~

200-240 V~, 3 A, 50/60 Hz

System I/O addresses

    The following table shows the location in I/O space of all directly I/O-accessible registers.

    Address Resource

    0000h - 000Fh

    DMA Controller 1

    0010h - 001Fh

    DMA Controller 1

    0020h - 0021h

    Interrupt Controller 1

    0022h - 0023h


    0024h - 0025h

    Interrupt Controller 1

    0026h - 0027h


    0028h - 0029h

    Interrupt Controller 1

    002Ah - 002Bh


    002Ch - 002Dh

    Interrupt Controller 1

    002Eh - 002Fh

    Super I/O Index and Data Ports

    0030h - 0031h

    Interrupt Controller 1

    0032h - 0033h


    0034h - 0035h

    Interrupt Controller 1

    0036h - 0037h


    0038h - 0039h

    Interrupt Controller 1

    003Ah - 003Bh


    003Ch - 003Dh

    Interrupt Controller 1

    003Eh - 003Fh


    0040h - 0043h

    Programmable Timers

    0044h - 004Fh


    0050h - 0053h

    Programmable Timers

    0054h - 005Fh


    0060h, 0064h

    Keyboard Controller

    0061h

    NMI Status and Control Register

    0063h

    NMI Status and Control Register

    0065h

    NMI Status and Control Register

    0067h

    NMI Status and Control Register

    0070h

    NMI Mask (bit 7) and RTC Address (bits 6::0)

    0072h

    NMI Mask (bit 7) and RTC Address (bits 6::0)

    0074h

    NMI Mask (bit 7) and RTC Address (bits 6::0)

    0076h

    NMI Mask (bit 7) and RTC Address (bits 6::0)

    0071h

    RTC Data

    0073h

    RTC Data

    0075h

    RTC Data

    0077h

    RTC Data

    0080h - 008Fh

    DMA Low Page Register

    0090h - 0091h

    DMA Low Page Register

    0092h

    System Control Port A (PC-AT control Port)

    0093h - 009Fh

    DMA Low Page Register

    0094h

    Video Display Controller

    00A0h - 00A1h

    Interrupt Controller 2

    00A4h - 00A15

    Interrupt Controller 2

    00A8h - 00A19

    Interrupt Controller 2

    00Ach - 00Adh

    Interrupt Controller 2

    00B0h - 00B1h

    Interrupt Controller 2

    00B2h

    Advanced Power Management Control

    00B3h

    Advanced Power Management Status

    00B4h - 00B5h

    Interrupt Controller 2

    00B8h - 00B9h

    Interrupt Controller 2

    00BCh - 00BDh

    Interrupt Controller 2

    00C0h - 00DFh

    DMA Controller 2

    00F0h

    Clear NPX error

    00F8h - 00FFh

    x87 Numeric Coprocessor

    0102h

    Video Display Controller

    0170h - 0177h

    Secondary Fixed Disk Controller (IDE)

    01F0h - 01F7h

    Primary Fixed Disk Controller (IDE)

    0200h - 0207h

    Game I/O Port

    0220h - 022Fh

    Serial Port A

    0238h - 023Fh

    Serial Port B

    0278h - 027Fh

    Parallel Port 3

    02E8h - 02Efh

    Serial Port B

    02F8h - 02FFh

    Serial Port B

    0338h - 033Fh

    Serial Port B

    0370h - 0375h

    Secondary Diskette

    0376h

    Secondary IDE

    0377h

    Secondary IDE/Diskette

    0378h - 037Fh

    Parallel Port 2

    03B4h - 03Bah

    Monochrome Display Port

    03BCh - 03BFh

    Parallel Port 1 (Primary)

    03C0h - 03CFh

    Video Display Controller

    03D4h - 03DAh

    Color Graphics Controller

    03E8h - 03EFh

    Serial Port A

    03F0h - 03F5h

    Diskette Controller

    03F6h - 03F7h

    Primary IDE - Sec. Diskette

    03F8h - 03FFh

    Serial Port A (Primary)

    0400h - 043Fh

    DMA Controller 1, Extended Mode Registers

    04D0h - 04D1h

    Interrupt Controllers 1 and 2 Control Register

    0678h - 067Ah

    Parallel Port (ECP)

    0778h - 077Ah

    Parallel Port (ECP)

    07BCh - 07BEh

    Parallel Port (ECP)

    0CA0 - CA3h

    BMC Registers

    0CF8h

    PCI CONFIG_ADDRESS Register

    0CF9h

    NBX Turbo and Reset control

    0CFCh

    PCI CONFIG_DATA Register

    46E8h

    Video Display Controller

Memory map

Address Range (hex) Amount Function

0 to 07FFFFh

640 KB

DOS region, base system memory

0A0000h to 0BFFFFh

128 KB

Video or SMM memory

0C0000h and 0DFFFFh

128 KB

Expansion card BIOS and buffer area

0E0000h to 0FFFFFh

128 KB

System BIOS

0E0000h to 0EFFFFh

2 MB

Extended system BIOS

FC000000h to FFFFFFFFh

64 MB

PCI memory space

Interrupts

    The following table suggests a logical interrupt mapping of interrupt sources. It reflects a typical configuration, but you can change these interrupts. Use the information to determine how to program each interrupt. The actual interrupt map is defined using configuration registers in the I/O controller. I/O Redirection Registers in the I/O APIC are provided for each interrupt signal. The signals define hardware interrupt signal characteristics for APIC messages sent to local APIC(s).

      Important

      If you disable either IDE controller to free the interrupt for that controller, you must physically unplug the IDE cable from the system board. Simply disabling the drive by configuring the SSU option does not make the interrupt available.

      Interrupt I/O APIC Level Description

      INTR

      INT0

      Processor interrupt

      NMI

      N/A

      NMI from PIC to processor

      IRQ1

      INT1

      Keyboard interrupt

      Cascade

      INT2

      Interrupt signal from second 8259

      IRQ3

      INT3

      Serial port A or B interrupt from SIO device (you can configure either)

      IRQ4

      INT4

      Serial port A or B interrupt from SIO device (you can configure either)

      IRQ5

      INT5

      Parallel port II

      IRQ6

      INT6

      Diskette port

      IRQ7

      INT7

      Parallel port

      IRQ8_L

      INT8

      RTC interrupt

      IRQ9

      INT9

      Signal control interrupt (SCI) used by ACPI-compliant operating system

      IRQ10

      INT10


      IRQ11

      INT11


      IRQ12

      INT12

      Mouse interrupt

      IRQ13

      INT13

      Co-processor interrupt

      IRQ14

      INT14

      Compatibility IDE interrupt from primary channel IDE devices 0 and 1

      IRQ15

      INT15


      SMI_L


      System management interrupt - general purpose indicator sourced through the PID to the processors

    DMA usage

      The following table lists the direct memory access (DMA) channels that the system typically uses and which ones are available for use by add-in devices.

      DMA Resource

      0

      Cascade

      1

      Available

      2

      Floppy Controller

      3

      Available

      4

      Redirect Cascade

      5

      Available

      6

      Available

      7

      Available