Optional Local Control Panel
9715 Server      Show Part Numbers

This is the optional local control panel (LCP) that can be installed in the Gateway® 9715 server. The LPC provides an intelligent front panel for the server, which lets you configure the server, monitor system status, and control the server from the panel. The LCD panel has its own microcontroller and is independent of the operating system. Its 4 × 20 display provides information directly from the Baseboard Management Controller (BMC) using the IPMB bus.

What are the menu options for the 9715 Local Control Panel module?

Refer to the following table for more information about the physical features of the module.

Item Name LED Function LED Color LED Description
A LCD screen Display of text
B Menu scroll up and down buttons Press these buttons to scroll up or down on the LCD
C Back button Press to move to the previous LCD screen
D Select button Press to enter a command or to select an option on the LCD
E Reset button Press to reset the system
F Hard drive status LED Indicates hard drive activity and fault status Green/amber
  • Green, on = A hard drive is being initialized
  • Green, blinking = A hard drive is active
  • Amber, on = Hard drive/slot failure
  • Amber, slow blinking (~ 1 Hz) = A predictive hard drive/slot failure or rebuild in process
  • Amber, fast blinking (~ 2.5 Hz) = Hard drive rebuild interrupted or rebuild on empty slot
  • G LAN 1 and LAN 2 activity LEDs Indicates LAN activity status Green
  • Off = Idle
  • On = Inactive state with no access
  • Blinking = Active state with access
  • H System status/fault LED Indicates system status Green/amber
  • Off = Not ready: AC power off or POST error
  • Green, on = Ready: System booted and ready
  • Green, blinking = Degraded: Processor or DIMM disabled
  • Amber, on = Critical alarm: Critical power supply, blower, voltage, or temperature failure
  • Amber, blinking = Non-critical alarm: Redundant power supply or blower failure. Non-critical blower, voltage, or temperature failure.
  • I Power button Press to turn on or off the system power
    J Power LED Indicates system power status Green
  • Off = Power off with no ACPI or S4/S5 state with ACPI
  • On = Power on with no ACPI or S0 state with ACPI
  • Blinking = S1 state with ACPI
  • K System ID LED Identifies the system via server management or locally Blue
  • Off = Not active
  • On = Active via switch: Cannot be turned off my Server Management
  • Blinking = Active via Server Management: Cannot be turned off by switch