Q: How do I remove and replace a power supply in the Gateway 9715 server?

A: Note: If two power supplies are installed in the server, you do not need to turn off the server.

Remove a power supply

  1. If only one power supply is installed, turn off the server. Otherwise continue with step 2.

  2. If applicable, examine the power supply LEDs to determine which is the failed module.
    View Picture

  3. At the rear of the server, disconnect the power cord for the power supply being removed.

  4. Press the power supply release button.
    View Picture
    View Picture

  5. Tilt the handle away from the server, and then pull the power supply out.
    View Picture

Replace a power supply

  1. With the power supply handle tilted outward, slide the module into the bay.
    View Picture

  2. Press the handle into the closed to position to secure the power supply in the bay.
    View Picture

  3. Connect the power cord.

  4. If applicable, turn on the server.

  5. The power supply module is ready if the green Power Good LED (top) and green AC OK LED (bottom) are lit.
    View Picture

    Note: If a second power supply module is added to the server, you must update the FRU/SDR after installation is complete. Refer to the User's Guide for more information.