Specifications
Part number 3501125,3501230,3501263,3501436,3501611

General
ProcessorsUp to two Intel Pentium III Coppermine or Tualitin processors operating at 1 GHz or faster
Cache256K or 512K, processor dependant
RAMFour DIMM sockets support up to 4.0 GB of PC/133 SDRAM
BIOSPhoenix flash BIOS for easy updates from disk
IDE interfaceTwo PCI controllers support as many as two ATAPI/IDE devices each (hard disks or CD-ROM drives) for a total of as many as four IDE devices (The chassis supports only the optional IDE CD-ROM drive.)
Disk drive interfaceThe disk drive controller is integrated on the motherboard. The chassis supports one slim-line floppy disk drive.
I/O portsOne serial port
One USB port on front panel
One PS/2 keyboard port
One PS/2 mouse port
Two RJ-45 network ports
One VGA video port
Power supply200-W power supply
SCSI interfacesIntegrated Adaptec AIC 7892 SCSI controller
Video chip setATI Rage XL AGP providing integrated SVGA video support with 4 MB of RAM
Network interfaceTwo Intel 82559 PCI Ethernet controllers
Server managementMonitoring, alerting, and logging of critical system information obtained from embedded sensors on the motherboard, including thermal levels, voltage levels, fan speeds, and chassis intrusion monitoring
Expansion slotsTwo 64-bit, 66-MHz PCI slots on the riser card.
Drive baysOne CD-ROM drive bay (CD-ROM drive optional)
One floppy disk drive bay
Three hot-plug (at least one is occupied by a 1-inch high hot-plug drive)
Mechanical
1U chassis case size1.67 × 16.73 × 24.5 inches (H × W × D)
Weight26.6 lbs
Environmental
Temperature
Non-operating
Operating
Maximum rate of change = 10° C per hour
–20.0 to 60.0° C (–4 to 140° F)
0 to 40° (32 to 104° F)
derated 0.5° for every 1,000 feet (305 m)
Humidity
Non-operating
Operating wet bulb
95% relative (non-condensing) at 30° C (86° F)
5 to 85%, not to exceed 33° C (91.4° F)
(with floppy disk drive or hard disk)
Shock
Operating
Packaged
10.0 g, 11 ms, 1/2 sine
Operational after 30-inch free fall (cosmetic damage may occur)
Vibration
Operating
Non-operating
 
0.0032 g2/Hz 5 – 200 Hz, -6dB/octave 200 – 500 Hz
0.015 g2/Hz 5 – 200 Hz, -6dB/octave 200 – 500 Hz
Altitude
Operating
Non-operating
 
10,000 feet maximum
50,000 feet maximum
Heat dissipation422 BTU (loaded)
988 BTU (maximum)
Electrical
AC input power
115 V –
230 V –
 
90 – 135 V –, 3.2 A
180 – 265 V –, 1.6 A
AC input frequency
115 V –
230 V –
 
47 – 63 Hz
47 – 63 Hz
Total power86.562 W (loaded)

Maximum temperature

Maximum temperature refers to the inlet air temperature, which is the ambient temperature within the rack cabinet, not the air temperature within the room.

BTU

The thermal output of a device is measured using the British thermal units (BTU) standard. One BTU equals the heat that raises the temperature of one pound of water by one degree Fahrenheit. In physical terms, 1 BTU equals 1,054 joules. System configuration of the loaded server is described in the following table.

DeviceConfigurationManufacturer/Type
CPU 1866 MHz (133 FSB)Intel Pentium III
CPU 2866 MHz (133 FSB)Intel Pentium III
Memory256 MBMicron 133
Hard disk 0SCSI 9.1GBIBM DDYS-T09170
Hard disk 1SCSI 9.1GBIBM DDYS-T09170
Hard disk 2SCSI 9.1GBIBM DDYS-T09170
CD-ROM driveSlim CDPanasonic CD-R177
Floppy disk driveSlim FloppyMitsumi

The BTU maximum rating was derived by taking the maximum wattage output of the power supply, which is 202.9 watss (W), dividing it by the lowest efficiency of the power supply, which is 70 percent or 0.70, and multiplying by the BTU conversion number of 3.41. These numbers are rated at the worst case or lowest efficiency of the power supply. Under nominal conditions, the power supply should perform above the 70 percent efficiency level, which lowers the BTU rating.