| Feature |
Specification |
| General |
| Temperature |
Operating: -10° to 50° C
Non-operating: -40° to 70° C |
| Relative Humidity |
Operating: 5% to 85% (non-condensing)
Non-operating: 5% to 95% (non-condensing) |
| Reliability |
100,000 hours at full load and 25° C ambient temperature |
| Safety Certifications |
UL
VDE or TUV |
| Current Nominal |
Maximum: 8.0 |
Maximum: 4.0 |
Amps |
| VIN Frequency |
Minimum: 47
Maximum: 63 |
Minimum: 47
Maximum: 63 |
Hertz |
| Output Voltage |
Values |
Unit |
| +12VA |
Minimum: 0.2
Regulation: 11.4-12.6
Maximum: 18 |
Amps |
| 5V |
Minimum: 0.3
Regulation: 4.75-5.25
Maximum: 22 |
Amps |
| 3.3V |
Minimum: 0.3
Regulation: 3.14-3.46
Maximum: 17 |
Amps |
| -12V |
Minimum: 0.0
Regulation: -10.8- -13.2
Maximum: 1.0 A |
Amps |
| 5Vsb |
Minimum: 0.0
Regulation: 4.75-5.25
Maximum: 2.0 |
Amps |
| +12VB |
Minimum: 0.2
Regulation: 11.4-12.6
Maximum: 18 |
Amps |