Running Check SMART Status Using GWSCAN 5.09
Note: Back up all data before proceeding.
- Place the Gateway Drivers CD 23.9 or later in the CD/DVD drive. If a window opens, close it.
- Restart the computer.
- During restart, from the Select an option menu, select 2. Boot from the CD-ROM, and then press the ENTER key.
View Picture
- From the next Select an option menu, select 1. English, 2. French, or 3. Spanish, and then press ENTER.
View Picture
- On the Gateway Utilities Main Menu screen, press the X key to select Exit to a Command Prompt.
View Picture
- At the command prompt, type: Gwscan.exe. Press ENTER.
- From the GWSCAN 5.09 - Data Lifeguard Diagnostics main menu, use the DOWN ARROW key to select Check Smart Status, and then press ENTER.
View Picture
- When the Smart Status test is complete, to return to the main menu press the ESC key.
View Picture
- Additional options may be selected at this time, or to exit the program, use the DOWN ARROW key to select Quit.
- Restart the computer.
|
 |
 |